Technical

Material properties

Every published figure, with the standard it was tested against — and, beside it, what an independent laboratory measured on a sample of the board.

Physical properties

PropertyStandardUnitStatedMeasured
DensityASTM C1185kg/m³1,250–1,4501,310.59
Modulus of rupture (dry)ASTM C1185MPa> 1012.63
Direct screw withdrawal strengthASTM D1037N> 1,7502,030.55
Thermal conductivityASTM C177W/(m·K)< 0.250.21
Linear coefficient of thermal expansionASTM D696mm/mm/°C7 × 10−6 to 10 × 10−68 × 10−6
pH valueLitmus test—10–1211.60
Moisture contentASTM C1185%< 1512.00

Every measured figure meets the figure Cemtone states. The stated column is what Cemtone publishes for the board. The measured column is what an independent laboratory found when it tested a sample against the same standards in September 2026.

Durability

TestStandardResult
ImpermeabilityBS EN 12467Pass
Freeze–thaw resistanceBS EN 12467Pass
Heat–rain resistanceBS EN 12467Pass
Warm water resistanceBS EN 12467Pass
Soak–dry resistanceBS EN 12467Pass
FireStandardResult
Non-combustibility testISO 1182Non combustible

A result about the material, not a rating for an assembly. ISO 1182 tests the board itself. A fire-rated wall, ceiling or shaft is a complete assembly, tested together for a period in minutes.

Testing and standards

The figures Cemtone publishes are ranges and minimums. In September 2026 a sample of the board was sent to an independent laboratory and measured, to find out whether the product meets what is claimed for it.

It does. Every one of the thirteen results met the published figure — density, modulus of rupture, screw withdrawal, thermal conductivity, thermal expansion, moisture content and pH, together with all five BS EN 12467 durability tests and non-combustibility.

Twelve of the thirteen were run to the standard Cemtone already publishes for them. The thirteenth, non-combustibility, was run to ISO 1182.

The laboratory report is held on file and is available to a specifier on request.

What this is, and what it is not. One sample, tested on one day, against the material standards named beside each row.

It is not a certification, an accreditation, or an audit of factory production, and nothing in it guarantees that a later batch matches this sample. A test report and a certification are different things, and this is the first.

Management system certification

Cemtone operates quality, environmental and occupational health and safety management systems certified to ISO 9001, ISO 14001 and ISO 45001. The certifying body is QSCert.

StandardWhat it certifies
ISO 9001 : 2015Quality management system
ISO 14001 : 2015Environmental management system
ISO 45001 : 2018Occupational health and safety management system

These certify the management system, not the board. They describe how the company runs its quality, environmental and safety processes. They do not state that the board meets any performance standard — the tables above do that.

Certificate numbers, issue and expiry dates and the scope of each certificate are not published here. Ask us for them before relying on a certificate in a tender.

Data sheet, 3 pages · brochure, 12 pages. Both open in a browser or download.

What the numbers mean

Non-combustible is a result about the material, not a rating for a wall. ISO 1182 tests whether the board itself contributes to a fire. It does not. A fire-rated wall or shaft is a complete assembly — board, framing, fixings, cavity and insulation — tested together for a period in minutes. Cemtone publishes the material result. Any period you need for a particular assembly has to come from a test of that assembly.

Density 1,250–1,450 kg/m³ is the mass of the material itself, not of a sheet. The weight you build with is on the board page: 8.1 kg/m² at 6 mm, up to 24.2 kg/m² at 18 mm, or 24 kg to 72 kg for a full 1220 × 2440 mm sheet.

Modulus of rupture above 10 MPa is the board's bending strength when dry, tested to ASTM C1185.

Screw withdrawal above 1,750 N is how hard a single screw resists being pulled straight out, tested to ASTM D1037.

pH 10–12 makes the board alkaline, which is normal for a cement product. It matters when choosing sealants, adhesives and paints — use products rated for an alkaline substrate.

Five BS EN 12467 passes cover impermeability, freeze–thaw, heat–rain, warm water and soak–dry. Freeze–thaw and heat–rain are the two an external specification turns on. BS EN 12467 also sorts a board into a category and a class. Neither is published, so ask for both before specifying the board externally.

The stated column is Cemtone's published manufacturer data. The measured column is one sample, tested on one day. Confirm both against a current test report before relying on them in a specification.

Next

Framing, spacing, gaps and fixing distances are on the installation page. Which thickness suits which job is on the board page.